Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Acoust Soc Am ; 155(3): 1895-1908, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38456732

RESUMO

Humans rely on auditory feedback to monitor and adjust their speech for clarity. Cochlear implants (CIs) have helped over a million people restore access to auditory feedback, which significantly improves speech production. However, there is substantial variability in outcomes. This study investigates the extent to which CI users can use their auditory feedback to detect self-produced sensory errors and make adjustments to their speech, given the coarse spectral resolution provided by their implants. First, we used an auditory discrimination task to assess the sensitivity of CI users to small differences in formant frequencies of their self-produced vowels. Then, CI users produced words with altered auditory feedback in order to assess sensorimotor adaptation to auditory error. Almost half of the CI users tested can detect small, within-channel differences in their self-produced vowels, and they can utilize this auditory feedback towards speech adaptation. An acoustic hearing control group showed better sensitivity to the shifts in vowels, even in CI-simulated speech, and elicited more robust speech adaptation behavior than the CI users. Nevertheless, this study confirms that CI users can compensate for sensory errors in their speech and supports the idea that sensitivity to these errors may relate to variability in production.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Humanos , Percepção Auditiva , Fala
2.
Behav Res Methods ; 56(3): 1433-1448, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37326771

RESUMO

Anonymous web-based experiments are increasingly used in many domains of behavioral research. However, online studies of auditory perception, especially of psychoacoustic phenomena pertaining to low-level sensory processing, are challenging because of limited available control of the acoustics, and the inability to perform audiometry to confirm normal-hearing status of participants. Here, we outline our approach to mitigate these challenges and validate our procedures by comparing web-based measurements to lab-based data on a range of classic psychoacoustic tasks. Individual tasks were created using jsPsych, an open-source JavaScript front-end library. Dynamic sequences of psychoacoustic tasks were implemented using Django, an open-source library for web applications, and combined with consent pages, questionnaires, and debriefing pages. Subjects were recruited via Prolific, a subject recruitment platform for web-based studies. Guided by a meta-analysis of lab-based data, we developed and validated a screening procedure to select participants for (putative) normal-hearing status based on their responses in a suprathreshold task and a survey. Headphone use was standardized by supplementing procedures from prior literature with a binaural hearing task. Individuals meeting all criteria were re-invited to complete a range of classic psychoacoustic tasks. For the re-invited participants, absolute thresholds were in excellent agreement with lab-based data for fundamental frequency discrimination, gap detection, and sensitivity to interaural time delay and level difference. Furthermore, word identification scores, consonant confusion patterns, and co-modulation masking release effect also matched lab-based studies. Our results suggest that web-based psychoacoustics is a viable complement to lab-based research. Source code for our infrastructure is provided.


Assuntos
Percepção Auditiva , Audição , Humanos , Psicoacústica , Audição/fisiologia , Percepção Auditiva/fisiologia , Audiometria , Internet , Limiar Auditivo/fisiologia , Estimulação Acústica
3.
bioRxiv ; 2023 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-37790457

RESUMO

The auditory system is unique among sensory systems in its ability to phase lock to and precisely follow very fast cycle-by-cycle fluctuations in the phase of sound-driven cochlear vibrations. Yet, the perceptual role of this temporal fine structure (TFS) code is debated. This fundamental gap is attributable to our inability to experimentally manipulate TFS cues without altering other perceptually relevant cues. Here, we circumnavigated this limitation by leveraging individual differences across 200 participants to systematically compare variations in TFS sensitivity to performance in a range of speech perception tasks. Results suggest that robust TFS sensitivity does not confer additional masking release from pitch or spatial cues, but appears to confer resilience against the effects of reverberation. Yet, across conditions, we also found that greater TFS sensitivity is associated with faster response times, consistent with reduced listening effort. These findings highlight the perceptual significance of TFS coding for everyday hearing.

4.
eNeuro ; 9(2)2022.
Artigo em Inglês | MEDLINE | ID: mdl-35193890

RESUMO

Neural phase-locking to temporal fluctuations is a fundamental and unique mechanism by which acoustic information is encoded by the auditory system. The perceptual role of this metabolically expensive mechanism, the neural phase-locking to temporal fine structure (TFS) in particular, is debated. Although hypothesized, it is unclear whether auditory perceptual deficits in certain clinical populations are attributable to deficits in TFS coding. Efforts to uncover the role of TFS have been impeded by the fact that there are no established assays for quantifying the fidelity of TFS coding at the individual level. While many candidates have been proposed, for an assay to be useful, it should not only intrinsically depend on TFS coding, but should also have the property that individual differences in the assay reflect TFS coding per se over and beyond other sources of variance. Here, we evaluate a range of behavioral and electroencephalogram (EEG)-based measures as candidate individualized measures of TFS sensitivity. Our comparisons of behavioral and EEG-based metrics suggest that extraneous variables dominate both behavioral scores and EEG amplitude metrics, rendering them ineffective. After adjusting behavioral scores using lapse rates, and extracting latency or percent-growth metrics from EEG, interaural timing sensitivity measures exhibit robust behavior-EEG correlations. Together with the fact that unambiguous theoretical links can be made relating binaural measures and phase-locking to TFS, our results suggest that these "adjusted" binaural assays may be well suited for quantifying individual TFS processing.


Assuntos
Percepção Auditiva , Estimulação Acústica/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA